FLUKE 115F Field Service Test Multimeter FIELD SERVICE TEST MULTIMETER
Fluke 115 Multimeter
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
Safety conformance: All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÃœV listed and VDE.
_
Specifications Maximum voltage between any terminaland earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3(500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3(500 Hz to 1 kHz) Continuity Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. Ohms Range/Resolution: 600.0 Ω / 0.1 Ω Range/Resolution: 6.000 kΩ / 0.001 kΩ Range/Resolution: 60.00 kΩ / 0.01 kΩ Range/Resolution: 600.0 kΩ / 0.1 kΩ Range/Resolution: 6.000 MΩ / 0.001 MΩ Accuracy: 0.9 % + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ Accuracy: 1.5 % + 2 Diode Test Range/Resolution: 2.00 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 µF / 0.01 µF Range/Resolution: 100.0 µF / 0.1 µF Range/Resolution: 9999 µF / 1 µF Range/Resolution: 100 µF to 1000 µF Accuracy: 1.9% + 2 Range/Resolution: > 1000 µF Accuracy: 5% + 20% Lo-Z Capacitance Range: 1 nF to 500 µF Accuracy: 10% + 2 typical AC amps true-rms (45 Hz to 500Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A overload for 30-seconds max DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A overload for 30-seconds max Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.9 Hz / 0.01 Hz Range/Resolution: 9.999 kHz / 0.001 kHz Range/Resolution: 50 kHz / 0.01 kHz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is s?nk1S11P
Weight: 0.757
‘Don’t Pay’ is the recommended retail price provided by the supplier or obtained from the manufacturer, or is the recently advertised price for the same product on a different or competing online platform or store. Catch may not have previously sold the product at the ‘Don’t Pay’ price.